Details of steel structure architectural design

Time:[2021-7-10]  Hits:2640

Many details need to be considered in the design of steel structure buildings, such as appropriate structural damping ratio, rigid column base design, beam column rigid connection design, floor design, etc. The details of steel structure architectural design are discussed in detail.

1. Suitable structural damping ratio

In the overall calculation of steel structure building, especially according to the requirements of seismic code, it is very necessary to choose the appropriate structural damping ratio. Unless otherwise specified, the damping ratio of building structure should be 0.05. Because different steel structures have different seismic influence coefficients, the selection of damping ratio should be based on the proportion of materials. Generally speaking, the more flexible the overall stiffness of the structure, the lower the damping ratio.

2. Rigid column base design

The commonly used column bases of steel structure buildings are embedded type, external type and exposed type, and the exposed type is more convenient for on-site installation and positioning. It should be noted that the stiffness of the column base is realized by the elastic or plastic deformation of the base plate. Therefore, in the design, it should be considered that the limit value of the story drift angle should have a certain margin, and the bending moment at the top of the column caused by the downward movement of the bending moment reacts on the bending point of the bottom steel column.

3. Floor design

Steel structure building has precast floor, cast-in-place floor, composite floor and so on. If precast slabs are used, floor joint cracking due to temperature variation and load distribution should be considered. In addition, in the floor design, attention should be paid to avoid one-way centralized layout, and try to form a two-way load-bearing structure.

4. Beam column rigid connection design.

Conventional design method or full section bending design method can be used to calculate the beam column rigid connection in steel structure buildings. When the bending capacity of steel beam flange is more than 70% of the total section capacity, the conventional design method can be used. If it is less than 70%, full section bending design method shall be adopted.

There are many factors to be considered in the design of steel structure buildings, and each link is very important.

Copyright:佛山市勝邦鋼結構有限公司 Foshan Shengbang Steel Structure Co., Ltd. Record Number:粵ICP備13078463號
主站蜘蛛池模板: 精品一区二区三区视频在线观看免 | 亚洲成人18 | 日本久草视频 | 男女晚上爱爱的视频在线观看 | 中国老妇另类xxxx | 在线观看一级毛片 | 国产三级精品美女三级 | 亚洲精品久久久中文字 | 国产成人亚洲综合一区 | 日本亚洲成高清一区二区三区 | 岛国毛片在线观看 | 手机看片精品国产福利盒子 | 国产精品久久福利网站 | 在线免费观看欧美 | 成人黄色免费 | 91九色精品国产 | 亚洲综合久久1区2区3区 | 中文字幕精品一区二区绿巨人 | 黄色免费三级 | 日本精品久久久久久久久免费 | 欧美大片一级特黄 | 性欧美video另类bd | 亚洲无线一二三区2021 | 亚洲精品午夜国产va久久成人 | 农村寡妇偷毛片一级 | 欧美成人性做爰网站免费 | 国产在线精品一区二区中文 | 亚洲第一免费视频 | 欧美一区二区精品系列在线观看 | 国模肉肉人体大尺度啪啪 | 男人天堂欧美 | 久久99国产精品 | 在线观看中文字幕亚洲 | 99热播 | 男人毛片| 精品在线一区 | 成人午夜天 | 日本不卡一二三区 | 亚洲精品色 | 和日本免费不卡在线v | 国产高清美女一级a毛片久久 |